Blog

The Best Vials To Use for PFAS Testing

Posted by Chrom Tech on 15th Oct 2025

The Best Vials To Use for PFAS Testing

Testing for PFAS requires an understanding of where contamination can originate—including the consumables used in your workflow. Choosing the right vial type is critical to ensure accurate, PFA …

read more

How to Select Chromatography Vials

Posted by Chrom Tech on 15th Oct 2025

How to Select Chromatography Vials

Choosing the right chromatography vial is essential for obtaining reliable, reproducible results. Factors such as sample volatility, volume, and light sensitivity all affect vial performance and data …

read more

Chrom Tech Products Related to COVID-19 Research

Posted by Chrom Tech on 15th Oct 2025

Chrom Tech Products Related to COVID-19 Research

The COVID-19 pandemic has reshaped global research priorities, accelerating demand for reliable analytical tools and consumables. At Chrom Tech, we are dedicated to supporting laboratories at the for …

read more

How To Reduce Column Pressure in HPLC

Posted by Chrom Tech on 15th Oct 2025

How To Reduce Column Pressure in HPLC

Pressure is a fundamental characteristic of every HPLC system, as solvents are pumped through tightly packed beds of fine particles within the column. Understanding what constitutes “normal&rd …

read more

To Cut or Not-to-Cut

Posted by Chrom Tech on 15th Oct 2025

To Cut or Not-to-Cut

When setting up an HPLC system, ensuring that tubing ends are flat, clean, and burr-free is essential for achieving accurate, reproducible results. A properly prepared connection minimizes dead volum …

read more

Offline vs. Online Degassing of HPLC Solvents

Posted by Chrom Tech on 15th Oct 2025

Offline vs. Online Degassing of HPLC Solvents

Gas bubbles and outgassing can significantly affect HPLC performance. Outgassing occurs when the dissolved gas concentration exceeds the solvent’s absorption capacity. Variables such as tempera …

read more

Essential List of Chromatography Supplies

Posted by Chrom Tech on 15th Oct 2025

Essential List of Chromatography Supplies

Chromatography is a fundamental analytical technique used to separate, identify, and quantify components within complex mixtures. It’s widely employed across research, pharmaceutical, and clin …

read more

Which 96-Well Plate Should I Use for LCMS?

Posted by Chrom Tech on 15th Oct 2025

Which 96-Well Plate Should I Use for LCMS?

Choosing the right 96-well plate for LCMS applications depends on several critical factors: rim design, sample recovery needs, and potential for analyte binding to the plate material. Selecting the r …

read more

Why You Should Filter Mobile Phase HPLC

Posted by Chrom Tech on 15th Oct 2025

Why You Should Filter Mobile Phase HPLC

Proper mobile phase filtration is one of the most critical yet overlooked steps in HPLC. Filtering your mobile phase helps extend instrument lifespan, improve reproducibility, and prevent costly dow …

read more

Why Use GC Derivatization Reagents

Posted by Chrom Tech on 15th Oct 2025

Why Use GC Derivatization Reagents

Gas Chromatography (GC) is used to separate and analyze volatile organic compounds. However, many compounds of analytical interest are not inherently volatile or thermally stable enough for GC analys …

read more

HPLC Column Care and Maintenance

Posted by Chrom Tech on 15th Oct 2025

HPLC Column Care and Maintenance

The HPLC column is one of the most critical and sensitive components in your chromatography system. As a consumable, it will eventually require replacement—but proper care and maintenance can d …

read more

What Are 96 Well Plates Used For?

Posted by Chrom Tech on 15th Oct 2025

What Are 96 Well Plates Used For?

96-well microplates—also known as deep well polypropylene microplates—are a cornerstone of modern life science laboratories. These plates are widely used for sample storage, preparation, …

read more

What Types of Fittings Are Used in HPLC?

Posted by Chrom Tech on 15th Oct 2025

What Types of Fittings Are Used in HPLC?

In any HPLC system, reliable connections are essential to prevent leaks, maintain pressure stability, and ensure accurate chromatographic performance. There are two main categories of HPLC fittings: …

read more

The Role of Chromatography in Cannabis Testing

Posted by Chrom Tech on 15th Oct 2025

The Role of Chromatography in Cannabis Testing

The use of cannabis in the United States continues to expand as more states legalize both medical and recreational consumption. With this growth, regulatory agencies have implemented mandatory testin …

read more

How Does a Pulse Dampener Work in an HPLC Pump?

Posted by Chrom Tech on 15th Oct 2025

How Does a Pulse Dampener Work in an HPLC Pump?

In high-performance liquid chromatography (HPLC), maintaining a consistent and smooth solvent flow is essential for achieving accurate, reproducible results. Even minor fluctuations in pressure or fl …

read more

What Column Should I Use for Proteomics?

Posted by Chrom Tech on 15th Oct 2025

What Column Should I Use for Proteomics?

Proteomics—the large-scale study of proteins—is a cornerstone of modern biological and pharmaceutical research. Understanding protein composition, structure, and interactions provides key …

read more

What is ICP-MS Used For?

Posted by Chrom Tech on 15th Oct 2025

What is ICP-MS Used For?

The Inductively Coupled Plasma–Mass Spectrometer (ICP-MS) is one of the most powerful and sensitive analytical instruments available for elemental analysis. Commonly known simply as ICP-MS, it …

read more

Which Pumps Are Used in HPLC?

Posted by Chrom Tech on 15th Oct 2025

Which Pumps Are Used in HPLC?

High-performance liquid chromatography (HPLC) relies on precision pumping systems to deliver solvents at a consistent, controlled flow rate and pressure. The right pump type ensures accurate separati …

read more

Environmental Applications of Chromatography

Posted by Chrom Tech on 15th Oct 2025

Environmental Applications of Chromatography

As global awareness of environmental challenges continues to rise, the need for advanced analytical tools has never been greater. Climate change, deforestation, and chemical pollution all threaten th …

read more

When to Change your HPLC Piston Seal

Posted by Chrom Tech on 15th Oct 2025

When to Change your HPLC Piston Seal

Example of polymer side vs. energizer side of seal.Note: Stainless steel energizer shown. Seal may also feature a fluoropolymer O-ring energizer (black O-ring). Proper maintenance of your HPLC pump …

read more

What Is the Difference Between UHPLC and HPLC?

Posted by Chrom Tech on 15th Oct 2025

What Is the Difference Between UHPLC and HPLC?

The two main differences between UHPLC and HPLC lie in their maximum system pressure ratings and the particle size used in the HPLC column stationary phase. Understanding these distinctions is key to …

read more

Understanding How mRNA Vaccines Are Produced

Posted by Chrom Tech on 15th Oct 2025

Understanding How mRNA Vaccines Are Produced

Messenger RNA (mRNA) vaccines represent one of the most significant advancements in modern medicine. These vaccines use lipid nanoparticles (LNPs) to safely deliver genetic instructions that teach th …

read more

PEEK Tubing: What It Is and the Different Types

Posted by Chrom Tech on 15th Oct 2025

PEEK Tubing: What It Is and the Different Types

Polyetheretherketone (PEEK) tubing is a high-performance polymer widely used in chromatography applications. Known for its mechanical strength, flexibility, and resistance to harsh solvents, PEEK has …

read more

Tips for How to Prime an HPLC Pump

Posted by Chrom Tech on 15th Oct 2025

Tips for How to Prime an HPLC Pump

Properly priming your HPLC pump is one of the simplest yet most essential steps in maintaining reliable system performance. Whether you’re setting up a new system, switching solvents, or restar …

read more

3 Ways to Reduce Long Lead Times

Posted by Chrom Tech on 15th Oct 2025

3 Ways to Reduce Long Lead Times

Over the past few years, laboratories have grown all too familiar with the phrase “supply chain issues.” Extended lead times can disrupt workflows, delay projects, and strain budgets. For …

read more

Vials vs. 96-Well Plates for Chromatography

Posted by Chrom Tech on 15th Oct 2025

Vials vs. 96-Well Plates for Chromatography

96-well plates and vials are both essential consumables in modern chromatography workflows. While vials have long been the industry standard, advances in automation and sample handling have made 96-w …

read more

How To Make an HPLC Connection With PEEK Tubing

Posted by Chrom Tech on 15th Oct 2025

How To Make an HPLC Connection With PEEK Tubing

Making an HPLC Connection With PEEK Tubing Creating a proper HPLC connection is essential for ensuring leak-free performance and consistent chromatographic results. With PEEK (Polyetheretherketone) t …

read more