RTK-930921E - Raptor Biphenyl, 1.8µm, 100x3.0mm HPLC Column (USP L11)
RestekRestek chemists became the first to combine the speed of superficially porous particles (also known as SPP or “core-shell” particles) with the resolution of highly selective USLC technology. This new breed of chromatographic column allows you to more easily achieve peak separation and faster analysis times with existing HPLC and UHPLC instrumentation.
- Ideal for bioanalytical testing applications like drug and metabolite analyses.
- Heightened selectivity and retention for compounds that are hard to resolve or elute early on C18 and other phenyl chemistries.
- Limits ionization suppression and allows simple, MS-friendly mobile phases.
- Part of Restek’s Raptor LC column line featuring 1.8, 2.7, and 5 μm SPP core-shell silica.
The innovative Biphenyl is Restek's most popular LC stationary phase because it is particularly adept at separating compounds that are hard to resolve or that elute early on C18 and other phenyl chemistries. As a result, the rugged Raptor Biphenyl column is extremely useful for fast separations in bioanalytical testing applications like drug and metabolite analyses, especially those that require a mass spectrometer (MS). Increasing retention of early-eluting compounds can limit ionization suppression, and the heightened selectivity helps eliminate the need for complex mobile phases that are not well-suited for MS detection.
Stationary Phase Category: Phenyl (L11)
Ligand Type: Biphenyl
Particle: 1.8 μm, 2.7 μm, or 5 μm superficially porous silica (SPP or "core-shell")
Pore Size: 90 Å
Carbon Load: 7% (1.8 μm), 7% (2.7 μm), 5% (5 μm)
End-Cap: yes
Surface Area: 125 m2/g (1.8 μm), 130 m2/g (2.7 μm), or 100 m2/g (5 μm)
Recommended Usage:
pH Range: 1.5–8.0
Maximum Temperature: 80 °C
Maximum Pressure: 1,034 bar/15,000 psi* (1.8 μm), 600 bar/8,700 psi (2.7 μm); 400 bar/5,800 psi (5 μm)
* For maximum lifetime, recommended maximum pressure for 1.8 μm particles is 830 bar/12,000 psi.
Properties:
- Increased retention for dipolar, unsaturated, or conjugated solutes.
- Enhanced selectivity when used with methanolic mobile phase.
- Ideal for increasing sensitivity and selectivity in LC-MS analyses.
Switch to a Biphenyl when: - Limited selectivity is observed on a C18.
- You need to increase retention of hydrophilic aromatics.
Brochures | |
---|---|
Restek HPLC ColumnsColumns for HPLC applications | Download |
Applications & Notes | |
The Big Pain231 Drugs and Metabolites | Download |
EtG/EtS in UrineFast Chromatographic Analysis | Download |
Blogs | |
Successful Stratregies for the Analysis of EtG and EtS in UrineFast and accurate analysis of blood alcohol indicators | |
Revisiting 'The Big Pain'Drug screening analysis in today's post-pandemic world | |
Quantitative Analysis of 58 Antipsychotics and Antidepressants in Human UrineAnalyzing prescription antidepressant and antisychotic drugs |
- Max Pressure:
- 1,034 bar/15,000 PSI
- Column Family:
- Restek Raptor LC Columns
- Phase:
- Biphenyl
- Particle Size:
- 1.8 um
- ID:
- 3.0 mm
- Length:
- 100 mm
- Unit of Measure:
- EA
- QTY:
- ea