H2PEM-260 - Hydrogen Generator, 260 cc/min
ParkerUltra-high purity hydrogen generators using a Proton Exchange Membrane from Parker Balston are designed as hazard free alternatives to high-pressure hydrogen cylinders. The PEM technology eliminates the use of liquid electrolytes for hydrogen generation. Deionized water and an electrical supply is all that is required to generate hydrogen for weeks of continuous operation. Optional automatic water-feed is available for remote installations or where minimal operator attention is required. With an output capacity of up to 260 ml/min, and delivery pressure adjustable up to 100 psi, one generator can supply 99.99999+% pure fuel gas for up to 7 FID’s or GC carrier gas. The compact design allows the generators to be installed directly in the laboratory eliminating the requirement for long hydrogen lines. Hydrogen generators are available with Remote Networking software. Remote Networking software allows up to 27 hydrogen generators to be activity controlled from one control PC and facilitates true cascading capabilities.
- Produces a continuous supply of 99.99999+% pure hydrogen gas at up to 6.9 bar (100psi)
- Designed to run 24 hours a day
- Compact, reliable and minimal maintenance
- Eliminate dangerous hydrogen cylinders from the laboratory
- 2 years standard cell warranty
- Ideal for GC combustion gas requirements
- CE and UL approved
H2PEM-260 Hydrogen Generator. Complete System including Proton Exchange Membrane (PEM) Cell, Internally Controlled PEM Cell Protection System with Pump Hydration, Simple Touch Screen User Interface, Color Changing Backlit Display System, Extra Large Internal Water Reservoir, Integrated Automatic Water Feed System, 1/8"" Compression Output Connection Port, RS485 Serial Connections Port for Optional USB Remote Monitoring and Control System, and (3) Year Standard Cell Warranty. See Parker.com for more information.
Hydrogen Purity | 99.9995% |
Flow Rate | 260 cc/min |
Outlet Port | 1/8"" compression |
Electrical Requirements | 100/230 VAC, 60/50 Hz |
Delivery Pressure | 5-100 psig +/- 0.5 psig |
Deionized Water Requirements | Deionized, ASTM II, >1 MOhm-cm |
Dimensions | 17 x 13.4 x 18 (43cm x 34.2cm x 45cm) |
Drop shipment required - additional shipping charges will be assessed at time of invoice
Brochures | |
---|---|
Gas GeneratorsParker Lab Gas Generators |
Download |
Blogs | |
Using Hydrogen as a Carrier Gas for Gas ChromatographyHydrogen is increasing in populartiy in the GC world as a carrier gas. Explore why more and more laboratories are turning to hydrogen. |
|
Are Hydrogen Generators Safe?Althought hydrogen gas cylinders are commonly found in the laboratory, they present a variety of safety risks and unexpected downtimes. Learn how to eliminate risks by making a simple switch. |
|
Do Your Really Need Helium as Your Carrier Gas?Unpredictable helium supply can be problematic. With ongoing shortages, it may be time to find an alternatve solution. |