Agilent Intuvo Guard Chips
The Intuvo Guard Chip is an innovative solution that replaces guard columns and extends column lifetime. The Guard Chip is a simple disposable chip that is easily installed and replaced in minutes. These chips prevent unwanted material from depositing on, and damaging the head of the column by providing almost a meter of sample flow path just before the Intuvo GC column. This protection eliminates the need for retention time adjustment and means that you never have to trim a column again. For applications where a Guard Chip is not needed, the jumper chip provides a short direct flow path. The guard and jumper chips are inlet-dependent so versions are available for split/splitless inlets and the multimode inlet.
| Description |
Part No. |
| Guard Chip, Intuvo, split/splitless inlet (2/pk) |
G4587-60565 |
| Jumper Chip, Intuvo, split/splitless inlet (ea) |
G4587-60575 |
| Guard Chip, Intuvo, multimode inlet (2/pk) |
G4587-60665 |
| Jumper Chip, Intuvo, multimode inlet (ea) |
G4587-60675 |
Agilent Intuvo Flow Chips
Intuvo Flow Chips are modular components that enable flexible configuration of the GC flow path. These chips provide connections between the inlet, column, and detector without the need for cumbersome ferrules. Furthermore, Intuvo Flow Chips are fitted with smart keys, so Intuvo knows exactly how to set itself up, whether for splitting, backflush, GC detectors, or mass spectrometry. The inlet chip provides a direct connection from the Guard Chip to the column. The D1, D2 and D2-MS chips provide a connection from the column to detector 1, detector 2, or the mass spectrometer. The remaining Flow Chips combine all the complex connections for backflush and splitting into a single device. Some of the Flow Chips require an Intuvo with an additional EPC module configured.
| Description |
Purpose |
Part No. |
| Inlet |
Connects Guard Chip to column |
G4581-60031 |
| Inlet splitter chip |
Splits flow from Guard Chip to two columns |
G4588-60601 |
| D1 |
Connects column to detector 1 |
G4581-60032 |
| D2 |
Connects column to detector 2 |
G4583-60621 |
| D2-MS |
Connects column to MS |
G4581-60033 |
| Mid column backflush to D1 |
Connects column to detector 1, mid column backflush capability |
G4588-60701 |
| Mid column backflush to D2 |
Connects column to detector 2, mid column backflush capability |
G4588-60721 |
| D1 post column backflush |
Connects column to detector 1, post column backflush capability |
G4588-60302 |
| D2-MS post column backflush |
Connects column to MS detector, post column backflush capability |
G4588-60322 |
| D1-D2 splitter chip, 1:1 |
Equally splits column effluent between two GC detectors |
G4588-60402 |
| D1-MS splitter chip, 1:1 |
Equally splits column effluent between GC detector and MS |
G4588-60502 |
Agilent Intuvo Detector Tails
| Description |
Part No. |
| Flow Chip, Intuvo, swaged MS tail |
G4590-60009 |
| Flow Chip, Intuvo, swaged HES MS tail |
G4590-60109 |
| Flow Chip, Intuvo, FID-TCD tail |
G4583-60331 |
| Flow Chip, Intuvo, ECD tail |
G4583-60333 |
| Flow Chip, Intuvo, NPD tail |
G4583-60334 |
| Flow Chip, Intuvo, FPD tail |
G4583-60335 |
| Flow Chip, Intuvo, XCD tail |
G4583-60336 |
Agilent Intuvo Gaskets
Intuvo uses ferrule-free face seals for all fittings within the sample gas flow path. Gaskets take the place of ferrules throughout the GC, providing the face seal between components of the Intuvo flow path. Easily replaced, these unique leak-free connections enable confident click-and-run column changes. The Intuvo gaskets are available in three types: polyimide, nickel, and as a plug. The polyimide gasket is for standard use up to 350 °C, while the nickel gasket provides a solution for high-temperature applications up to 450 °C. The plug gasket can be used to check for leaks and for troubleshooting the flow path.
| Description |
Part No. |
| Gasket, Intuvo, polyimide (5/pk) |
5190-9072 |
| Gasket, Intuvo, nickel (2/pk) |
5190-9073 |
| Gasket plug, Intuvo, polyimide (2/pk) |
5190-9074 |
Agilent Intuvo Supplies
| Description |
Part No. |
| Unique Detector Parts |
| Universal Fit Flame Ionization Detector jet, 0.011 inch inner diameter |
5200-0176 |
| Compression Bolts |
| Compression bolt, detector tail |
G4583-20005 |
| Compression bolt, Intuvo |
G4581-60260 |
| Compression bolt, Guard Chip |
G4581-20006 |
| Compression bolt, split/splitless inlet |
G4582-20085 |
| Compression bolt, multimode inlet |
G4586-20027 |
| Tools |
| Wrench, open end, 0.3125" |
8710-2801 |
| Wrench, open end, 0.25" |
8710-2800 |
| Torque driver kit, includes G4581-20522 and 8710-2790 |
5190-9571 |
| Torque driver extension* |
G4581-20522 |
| Screw driver, torque, preset adjustable* |
8710-2790 |
| Exhaust Vent |
| Exhaust Vent |
G4580-68300 |
| *Included in 5190-9571 |