Agilent Supplies for HP 5890 Gas Chromatograph

Chrom Tech is committed to optimizing your laboratory’s productivity. This quick reference guide lists the most commonly ordered supplies and parts for the Agilent HP 5890 Gas Chromatograph. Use this list to find the right components quickly and minimize instrument downtime.

General Supplies

Description Part No.
Column nut (2/pk) 5181-8830

Ferrules and Septa

Description Part No.
0.5 mm ID graphite ferrules (10/pk) for 0.1–0.32 mm columns 5080-8853
1.0 mm ID graphite ferrules (10/pk) for 0.53 mm columns 5080-8773
Septa, 11 mm high-temperature (50/pk) 5183-4757
Septa, 5 mm through-hole (25/pk) 5181-1260
Septa, 5 mm long-life (50/pk) 5183-4762

Merlin Microseal

Description Part No.
Starter kit (1 microseal and 1 nut) 5182-3442
Replacement microseal 5182-3444

Split/Splitless Inlet Supplies

Description Part No.
Septum retainer nut 18740-60835
Inlet liner O-ring, non-stick fluorocarbon, 10/pk 5188-5365
Double taper splitless liner (deactivated) 5181-3315
Split/splitless liner with glass wool 19251-60540
Single taper liner (deactivated) splitless 5181-3316
GC inlet seal, gold plated, with washer 5188-5367

Cool On-Column Inlet Supplies

Description Part No.
Insert for 530 µm capillary columns (no rings) 19245-20580
Insert for 320 µm columns (5 silver rings) 19245-20525
Insert for 200 µm columns (1 ring, manual injection) 19245-20510
Insert for 250 µm columns (6 rings, automatic injection) 19245-20515
Spring (for 5890 Series II use) 19245-60760
Septum nut base assembly (for 5890 Series II) 19245-80520

Packed Inlet Supplies

Description Part No.
Septum retainer nut (universal packed inlet) 19243-60505
Viton O-rings (12/pk) 5080-8898
530 µm column adapter 19244-80540
1/4-in. column adapter 19243-80520
1/8-in. column adapter 19243-80530
Glass insert (disposable, 25/pk) 5080-8732
Glass insert (deactivated, 5/pk) 5181-3382
1/4-in. tubing nut, brass (10/pk) 5180-4105

Tools and Gas Management Supplies

Description Part No.
CrossLab CS Electronic Leak Detector G6693A
GC Buddy 5182-9765
Two-stage regulator (CGA 580) 125 psig max 5183-4644
Installation kit with ferrules, nuts, tubing and gas traps 19199N
Installation kit with tools (no gas purifiers) 19199M
ADM Flow Meter G6691A
Oxygen/moisture trap OT3-2
Hydrocarbon “S” trap (activated charcoal) 5060-9096
Moisture “S” trap (preconditioned) 5060-9084

Flame Ionization Detector (FID) Supplies

Description Part No.
Collector nut 19231-20940
Spring washer (10/pk) 5181-3311
FID collector assembly G1531-60690
FID jet, universal fit, 0.011 inch id 5200-0176
FID jet, universal fit, 0.018 inch id 5200-0177
FID flow measuring insert 19301-60660
FID cleaning kit (reamers, mini brush, handle) 9301-0985

Nitrogen Phosphorus Detector (NPD) Supplies

Description Part No.
White ceramic bead assembly (standard sensitivity) G1534-60570
Black ceramic bead assembly (high sensitivity) 5183-2007
FID jet, universal fit, 0.011 inch id 5200-0176
FID jet, universal fit, 0.018 inch id 5200-0177

FID/NPD Adapters

Description Part No.
FID/NPD adapter for capillary columns 19244-80610
Ferrule, 1/4 in. Vespel 5080-8774
530 µm 1.0 mm ID graphite ferrule 5080-8773
320 µm 0.5 mm ID graphite ferrule 5080-8853
1/4 in. nut, brass (10/pk) 5180-4105

Thermal Conductivity Detector (TCD) Supplies

Description Part No.
TCD capillary column adapter seal and nut G1532-80540

Electron Capture Detector (ECD) Supplies

Description Part No.
Micro-ECD wipe test kit 18713-60050

Crimping and Decapping Supplies

Description Part No.
Electronic crimper for 2 mL vials with battery and charger 5183-4763
Electronic decapper for 2 mL vials with battery and charger 5184-3567
Manual crimp holder without crimp head 5062-2495
Crimp head for 12 mm caps (for manual crimp holder) 5001-3755
Decapper head for 12 mm caps (for manual crimp holder) 5001-3758

This information is subject to change without notice.
© Chrom Tech, Inc. Adapted from Agilent Technologies, Inc. 2005 (5989-2200EN)