Chrom Tech is dedicated to helping you keep your GC systems running at peak performance. This quick reference guide highlights the most commonly ordered parts and supplies for the Agilent 7694 Headspace Sampler. Use it to easily locate the items you need and minimize instrument downtime.
Vials, Caps, and Septa
| Description |
Part No. |
| Headspace crimp top, flat bottom vials, 20 mL, 100/pk |
5182-0837 |
| Headspace crimp top, flat bottom vials, 10 mL, 100/pk |
5182-0838 |
| Silver aluminum crimp caps with 20 mm, PTFE/silicone septa, 100/pk |
5183-4477 |
| Silver aluminum crimp caps with safety feature, 20 mm, PTFE/silicone septa, 100/pk |
5183-4478 |
| Silver aluminum crimp caps with 20 mm molded PTFE/butyl septa, 100/pk |
5183-4479 |
| Silver aluminum crimp caps with safety feature, 20 mm molded PTFE/butyl septa, 100/pk |
5183-4480 |
| Vial kit: 20 mL Headspace crimp top, flat bottom vials, silver aluminum one-piece crimp caps with safety feature, molded gray PTFE/black butyl septa, 100/pk |
5182-0839 |
| Vial kit: 20 mL Headspace crimp top, flat bottom vials, silver aluminum one-piece crimp caps with safety feature, PTFE/white silicone septa, 100/pk |
5182-0840 |
Needles
| Description |
Part No. |
| Needle, headspace transfer line, deactivated 0.5 mm OD |
2322590004 |
| Needle for transfer line, 0.25 mm ID, 0.5 mm OD, nickel |
301-016-HSP |
| Needle, headspace transfer line, deactivated 0.7 mm OD |
2322590005 |
| Needle for transfer line, 0.4 mm ID, 0.8 mm OD, nickel |
301-015-HSP |
| Needle assembly vial probe, deactivated |
301-220-HSP |
| Needle assembly (vial probe) |
301-013-HSP |
Fittings
Tubing and Transfer Lines
| Description |
Part No. |
| Sample loop, 1 mL, deactivated |
2321700003 |
| Sample loop, 1 mL, nickel |
321-055-HSP |
| Sample loop, 3 mL, deactivated |
2321700004 |
| Sample loop, 3 mL, nickel |
321-056-HSP |
| Tube, needle, 6-port valve, deactivated |
301-212-HSP |
| Tube, needle, 6-port valve, nickel |
301-169-HSP |
| Tube, vent-valve stainless steel |
301-170-HSP |
| Sensor tube, 125 mm PTFE |
321-057-HSP |
| Restrictor, stainless steel |
321-002-HSP |
| Transfer line, deactivated, 1 m |
301-211-HSP |
| Transfer line, 1 m, nickel |
301-152-HSP |
| Transfer line, 80 cm, nickel |
301-011-HSP |
Repair, Leak Test, and OQ/PV Supplies
| Description |
Part No. |
| Strain relief septum nut |
301-205-HSP |
| Oven adaptor for 10 mL vials |
301-017-HSP |
| Tray adaptors for 10 mL vials, 25/pk |
300-301-HSP |
| Headspace leak test kit |
G1888-60701 |
| OQ/PV Headspace Sample |
5182-9733 |
Valves
| Description |
Part No. |
| Valve, solenoid vent Kalrez |
3600500001 |
| Valve, solenoid vial pressurization |
3600500002 |
| Pressure regulator |
330-086-HSP |
| Flow controller |
330-055-HSP |
This information is subject to change without notice.
© Chrom Tech, Inc. Adapted from Agilent Technologies, Inc. 2007 (5989-6723EN)