Agilent 6850 Gas Chromatograph Supplies

Chrom Tech is dedicated to optimizing your laboratory’s productivity. This quick reference guide lists the most commonly ordered supplies and parts for the Agilent 6850 gas chromatograph. Use this list to easily find the parts you need and reduce instrument downtime.

General Supplies

Description Part No.
Column nut (2/pk) 5183-4732

Ferrules and Septa

Description Part No.
0.5 mm ID graphite ferrules (10/pk) for 0.1–0.32 mm columns 5080-8853
1.0 mm ID graphite ferrules (10/pk) for 0.53 mm columns 5080-8773

Preconditioned Septa

Description Part No.
Septa, 11 mm high-temperature BTO (50/pk) 5183-4757
Septa, 11 mm advanced green (50/pk) 5183-4759
Septa, 11 mm long-life (50/pk) 5183-4761

Merlin Microseal

Description Part No.
Starter kit (1 microseal and 1 nut) 5182-3442
Replacement microseal 5182-3444

Tools and Gas Management Supplies

Description Part No.
CrossLab CS Electronic Leak Detector G6693A
GC Buddy 5182-9765
Two-stage regulator, brass, 125 psig max, CGA 580 5183-4644
Installation kit with ferrules, nuts, tubing, and gas traps 19199N
Installation kit with tools (no gas purifiers) 19199M
ADM Flow Meter G6691A
Oxygen/moisture trap OT3-2
Hydrocarbon “S” trap, activated charcoal 5060-9096
Moisture “S” trap, preconditioned 5060-9084

Split/Splitless Inlet Supplies

Description Part No.
4 mm ID, 900 µL split liner with glass wool 19251-60540
4 mm ID, 900 µL single taper liner (deactivated) 5181-3316
4 mm ID, 900 µL single taper liner with glass wool (deactivated) 5062-3587
Double taper splitless liner (deactivated) 5181-3315
Graphite O-rings for split applications (10/pk) 5180-4168
Graphite O-rings for splitless applications (10/pk) 5180-4173
Inlet liner O-ring, non-stick fluorocarbon, 10/pk 5188-5365
GC inlet seal, gold plated, with washer 5188-5367

Packed Port Inlet Supplies

Description Part No.
Viton O-rings (12/pk) 5080-8898
Vespel column ferrules (10/pk) 5080-8774
Column nut 1/4-in. brass (10/pk) 5180-4105
530 µm column adapter 19244-80540
1/8-in. column adapter 19243-80530
1/4-in. column adapter 19243-80540
Glass insert, disposable (25/pk) 5080-8732
Glass insert, disposable/deactivated (5/pk) 5181-3382

Flame Ionization Detector (FID) Supplies

Description Part No.
Collector nut 19231-20940
Spring washer (10/pk) 5181-3311
FID collector assembly G1531-60690
FID jet, universal fit, 0.011 inch id 5200-0176
FID jet, universal fit, 0.018 inch id 5200-0177
FID flow measuring insert 19301-60660
FID cleaning kit (reamers, mini brush, handle) 9301-0985

Thermal Conductivity Detector (TCD) Supplies

Description Part No.
TCD cap column adapter seal and nut G1532-80540

This information is subject to change without notice.
© Chrom Tech, Inc. Adapted from Agilent Technologies, Inc. 2005 (5989-2199EN)